品牌:西门子6XV183O-0EH1O紫色电缆
起订:20米
供应:9999米
发货:1天内
信息标签:西门子6XV183O-0EH1O紫色电缆,供应,电子、电工,工控系统及装备
Order number |
6XV1830-0EH10 |
6XV1831-2A |
6XV1830-0JH10 |
6XV1830-0GH10 |
|
---|---|---|---|---|---|
Product type designation |
PROFIBUS FC Standard Cable GP |
PROFIBUS FC Standard Cable IS GP |
PROFIBUS FC Robust Cable |
PROFIBUS FC Food Cable |
|
Product description |
Standard bus cable (2-core), sold by the meter, unassembled |
Standard bus cable for fast installation, sold by the meter, unassembled |
Special bus cable (2-core), sold by the meter, unassembled |
Bus cable (2-core), sold by the meter, unassembled |
|
Suitability for use |
Standard cable specially designed for fast, permanent installation |
Used for intrinsically safe distributed I/O systems for permanent installation |
For use in chemically and mechanically demanding environments |
For use in the food, beverages and tobacco industries |
|
Cable designation |
02YSY (ST) CY 1x2x0,64/2,55-150 VI KF 40 FR |
02YSY (ST) CY 1x2x0,64/2,55 BL KF40 FR |
02YSY (ST) C11Y 1x2x0,64/2,55-150 VI KF 40 FR |
02YSY (ST) C2Y 1x2x0,64/2,55-150 KF 40 |
|
Electrical data |
|||||
Damping ratio per length |
|||||
|
2.5 dB/km |
2.5 dB/km |
2.5 dB/km |
2.5 dB/km |
|
|
4 dB/km |
4 dB/km |
4 dB/km |
4 dB/km |
|
|
22 dB/km |
22 dB/km |
22 dB/km |
22 dB/km |
|
|
42 dB/km |
42 dB/km |
42 dB/km |
42 dB/km |
|
Impedance |
|||||
|
150 Ω |
150 Ω |
150 Ω |
150 Ω |
|
|
270 Ω |
270 Ω |
270 Ω |
270 Ω |
|
|
185 Ω |
185 Ω |
185 Ω |
185 Ω |
|
|
150 Ω |
150 Ω |
150 Ω |
150 Ω |
|
Relative symmetrical tolerance |
|||||
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
Loop resistance per length maximum |
110 mΩ/m |
110 mΩ/m |
110 mΩ/m |
110 mΩ/m |
|
Shield resistance per length maximum |
9.5 Ω/km |
9.5 Ω/km |
9.5 Ω/km |
9.5 Ω/km |
|
Insulation resistance coefficient |
16 000 GΩ·m |
||||
Capacity per length at 1 kHz |
28.5 pF/m |
28.5 pF/m |
28.5 pF/m |
28.5 pF/m |
|
Operating voltage |
|||||
|
100 V |
100 V |
100 V |
100 V |
|
Mechanical data |
|||||
Number of electrical cores |
2 |
2 |
2 |
2 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
|
Core diameter |
|||||
|
0.64 mm |
||||
Outer diameter |
|||||
|
0.65 mm |
0.64 mm |
0.65 mm |
0.65 mm |
|
|
2.55 mm |
2.55 mm |
2.55 mm |
2.55 mm |
|
|
5.4 mm |
5.4 mm |
5.4 mm |
5.4 mm |
|
|
8 mm |
8 mm |
8 mm |
8 mm |
|
Symmetrical tolerance of the outer diameter of cable sheath |
0.4 mm |
0.4 mm |
0.4 mm |
0.4 mm |
|
Material |
|||||
|
PE |
PE |
PE |
PE |
|
|
PVC |
PVC |
PVC |
PVC |
|
|
PVC |
PVC |
PUR (TPE-U) |
PE; Outer cover made of PE is especially suitable for the food processing industry |
|
Color |
|||||
|
red/green |
red/green |
red/green |
red/green |
|
|
Violet |
blue |
Violet |
Black |
|
Bending radius |
|||||
|
37.5 mm |
37.5 mm |
75 mm |
30 mm |
|
|
75 mm |
75 mm |
150 mm |
60 mm |
|
Tensile load maximum |
100 N |
100 N |
100 N |
100 N |
|
Weight per length |
80 kg/km |
80 kg/km |
71 kg/km |
67 kg/km |
|
Permitted ambient conditions |
|||||
Ambient temperature |
|||||
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
|
Burning behavior |
flame resistant according to IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4) |
flame resistant according to IEC 60332-3-24 (Category C) |
flame resistant according to IEC 60332-1 |
inflammable |
|
Chemical resistance |
|||||
|
oil resistant according to IEC 60811-2-1 (4 hours / 70°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
|
|
Conditional resistance |
Conditional resistance |
resistant |
Conditional resistance |
|
|
conditional resistance |
conditional resistance |
conditional resistance |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
resistant |
|
Product properties, functions, components general |
|||||
Product feature |
|||||
|
No |
No |
No |
No |
|
|
Yes |
Yes |
Yes |
Yes |
|
Standards, specifications, approvals |
|||||
UL/ETL listing 300 V Rating |
Yes; c(UL)us, CMG / CL3 / Sun Res |
Yes; CMG / CL3 / Sun Res |
Yes; c(UL)us, CMX |
No |
|
UL/ETL style 600 V Rating |
Yes |
Yes |
No |
No |
|
Certificate of suitability |
|||||
|
Yes |
Yes |
Yes |
Yes |
|
|
Yes |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Marine classification association |
|||||
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
Order number |
6XV1830-3FH10 |
6XV1831-2K |
6XV1830-3EH10 |
6XV1831-2L |
|
---|---|---|---|---|---|
Product type designation |
PROFIBUS FC Ground Cable |
PROFIBUS FC Flexible Cable |
PROFIBUS FC Trailing Cable |
PROFIBUS FC Trailing Cable |
|
Product description |
Special bus cable (2-core) with additional protective jacket, sold by the meter, unassembled |
Flexible bus cable (2-core), sold by the meter, unassembled |
Highly flexible bus cable (2-core), sold by the meter, unassembled |
Highly flexible bus cable (2-core), sold by the meter, unassembled |
|
Suitability for use |
Used for buried cables |
For occasionally moved machine parts |
Continuous motion control in a cable carrier |
Continuous motion control in a cable carrier |
|
Cable designation |
02YSY (ST) CY2Y 1x2x0,64/2,55-150 SW KF 40 |
02YH (ST) C11Y 1x2x0,65/2,56-150 LI KF40 FRNC FC VI |
02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR petrol |
02YY (ST) C11Y 1x2x0,65/2,56-150 LI KF 40 FR VT FC |
|
Electrical data |
|||||
Damping ratio per length |
|||||
|
2.5 dB/km |
3 dB/km |
3 dB/km |
3 dB/km |
|
|
4 dB/km |
4 dB/km |
4 dB/km |
4 dB/km |
|
|
22 dB/km |
25 dB/km |
25 dB/km |
25 dB/km |
|
|
42 dB/km |
49 dB/km |
49 dB/km |
49 dB/km |
|
Impedance |
|||||
|
150 Ω |
150 Ω |
150 Ω |
150 Ω |
|
|
270 Ω |
270 Ω |
270 Ω |
270 Ω |
|
|
185 Ω |
185 Ω |
185 Ω |
185 Ω |
|
|
150 Ω |
150 Ω |
150 Ω |
150 Ω |
|
Relative symmetrical tolerance |
|||||
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
|
10 % |
10 % |
10 % |
10 % |
|
Loop resistance per length maximum |
110 mΩ/m |
133 mΩ/m |
133 mΩ/m |
133 mΩ/m |
|
Shield resistance per length maximum |
9.5 Ω/km |
15 Ω/km |
14 Ω/km |
14 Ω/km |
|
Insulation resistance coefficient |
16 000 GΩ·m |
||||
Capacity per length at 1 kHz |
28.5 pF/m |
28 pF/m |
28 pF/m |
28 pF/m |
|
Operating voltage |
|||||
|
100 V |
100 V |
100 V |
100 V |
|
Mechanical data |
|||||
Number of electrical cores |
2 |
2 |
2 |
2 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
|
Outer diameter |
|||||
|
0.65 mm |
0.67 mm |
0.67 mm |
0.67 mm |
|
|
2.55 mm |
2.56 mm |
2.56 mm |
2.56 mm |
|
|
5.4 mm |
5.4 mm |
5.4 mm |
5.4 mm |
|
|
10.8 mm |
8 mm |
8 mm |
8 mm |
|
|
The cable (diameter 8.0 mm +-0.4 mm) has an additional black outer cover (diameter 10.8 mm +-0.5 mm) as protection against damage if laid in the ground. because of outer diameter > 8 mm: Bus connectors can only be connected after removing the outer cover. |
||||
Symmetrical tolerance of the outer diameter of cable sheath |
0.5 mm |
0.4 mm |
0.4 mm |
0.4 mm |
|
Material |
|||||
|
PE |
PE |
PE |
PE |
|
|
PVC |
FRNC |
PVC |
PVC |
|
|
PE/PVC; PVC (sheath of the cable), PE (additional outer sheath) |
PUR (TPE-U) |
PUR (TPE-U) |
PUR (TPE-U) |
|
Color |
|||||
|
red/green |
red/green |
red/green |
red/green |
|
|
Black |
Violet |
petrol |
Violet |
|
Bending radius |
|||||
|
41 mm |
40 mm |
40 mm |
40 mm |
|
|
81 mm |
120 mm |
|||
|
120 mm |
120 mm |
|||
Number of bending cycles |
3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 120 mm (15x D), a speed of 4 m/s and an acceleration of 4 m/s² |
3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 120 mm (15x D) and an acceleration of 4 m/s² |
|||
Tensile load maximum |
100 N |
100 N |
100 N |
100 N |
|
Weight per length |
117 kg/km |
70 kg/km |
77 kg/km |
77 kg/km |
|
Permitted ambient conditions |
|||||
Ambient temperature |
|||||
|
-40 ... +60 °C |
-20 ... +60 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +60 °C |
-40 ... +60 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +60 °C |
-40 ... +60 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
-40 ... +60 °C |
-40 ... +60 °C |
-40 ... +60 °C |
-40 ... +60 °C |
|
|
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN 47250 part 4 respectively DIN VDE 0472 |
|
Ambient condition for operation |
Limited segment length (see manual for PROFIBUS networks) |
Limited segment length (see manual for PROFIBUS networks) |
Limited segment length (see manual for PROFIBUS networks) |
||
Burning behavior |
inflammable |
flame resistant according to IEC 60332-1-2 |
flame resistant according to IEC 60332-1-2 |
flame resistant according to IEC 60332-1-2 |
|
Chemical resistance |
|||||
|
oil resistant according to IEC 60811-2-1 (4 hours / 70°C) |
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
|
|
Conditional resistance |
resistant |
resistant |
resistant |
|
|
conditional resistance |
conditional resistance |
conditional resistance |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant / Sunlight resistant acc. to UL 444 Sec. 7.12 |
resistant |
resistant |
resistant |
|
Product properties, functions, components general |
|||||
Product feature |
|||||
|
No |
Yes |
No |
No |
|
|
Yes |
Yes |
Yes |
Yes |