品牌:Siemens/西门子
起订:1台
供应:100台
发货:1天内
信息标签:D445-2DP/PN6AU1445-2AD00-0AA0,供应,电子、电工,工控系统及装备
Order number |
|
6AU1425-2AA00-0AA0 |
6AU1425-2AD00-0AA0 |
6AU1435-2AA00-0AA0 |
6AU1435-2AD00-0AA0 |
6AU1445-2AD00-0AA0 |
6AU1455-2AD00-0AA0 |
|
---|---|---|---|---|---|---|---|---|
product brand name |
SIMOTION |
SIMOTION |
SIMOTION |
SIMOTION |
SIMOTION |
SIMOTION |
||
Product type designation |
D425-2 DP |
D425-2 DP/PN |
D435-2 DP |
D435-2 DP/PN |
D445-2 DP/PN |
D455-2 DP/PN |
||
Performance class for motion control system |
BASIC Performance |
BASIC Performance |
STANDARD Performance |
STANDARD Performance |
HIGH Performance |
ULTRA-HIGH Performance |
||
Version of the motion control system |
Multiple-axis system |
Multiple-axis system |
Multiple-axis system |
Multiple-axis system |
Multiple-axis system |
Multiple-axis system |
||
PLC and motion control performance |
||||||||
Number of axes maximum |
16 |
16 |
32 |
32 |
64 |
128 |
||
Minimum PROFIBUS cycle clock |
ms |
1 |
1 |
1 |
1 |
1 |
1 |
|
Minimum PROFINET send cycle clock |
ms |
-- |
0.25 |
-- |
0.25 |
0.25 |
0.25 |
|
Minimum servo cycle clock |
ms |
0.5 |
0.5 |
0.5 |
0.25 |
0.25 |
0.25 |
|
Minimum interpolator cycle clock |
ms |
0.5 |
0.5 |
0.5 |
0.25 |
0.25 |
0.25 |
|
Minimum servo cycle clock note |
-- |
-- |
-- |
0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST |
0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST |
0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST |
||
Integrated drive control |
||||||||
Maximum number of axes for integrated drive control |
||||||||
|
6 |
6 |
6 |
6 |
6 |
6 |
||
|
6 |
6 |
6 |
6 |
6 |
6 |
||
|
12 |
12 |
12 |
12 |
12 |
12 |
||
|
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
||
Memory |
||||||||
RAM (work memory) |
Mbyte |
64 |
64 |
86 |
86 |
160 |
320 |
|
Additional RAM work memory for Java applications |
Mbyte |
20 |
20 |
20 |
20 |
20 |
20 |
|
RAM disk (load memory) |
Mbyte |
31 |
31 |
41 |
41 |
56 |
76 |
|
Retentive memory |
kbyte |
364 |
364 |
364 |
364 |
512 |
512 |
|
Persistent memory (user data on CF) |
Mbyte |
300 |
300 |
300 |
300 |
300 |
300 |
|
Communication |
||||||||
DRIVE-CLiQ Interfaces |
4 |
4 |
6 |
6 |
6 |
6 |
||
USB Interfaces |
2 |
2 |
2 |
2 |
2 |
2 |
||
Industrial Ethernet Interfaces |
3 |
2 |
3 |
2 |
2 |
2 |
||
PROFIBUS Interfaces |
2 |
2 |
2 |
2 |
2 |
2 |
||
|
Equidistant and isochronous; Can be configured as master or slave |
Equidistant and isochronous; Can be configured as master or slave |
Equidistant and isochronous; Can be configured as master or slave |
Equidistant and isochronous; Can be configured as master or slave |
Equidistant and isochronous; Can be configured as master or slave |
Equidistant and isochronous; Can be configured as master or slave |
||
PROFINET Interfaces |
0 |
1 |
0 |
1 |
1 |
1 |
||
|
-- |
1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD) |
-- |
1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD) |
1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD) |
1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD) |
||
General technical data |
||||||||
Fan |
Double fan/battery module included in scope of delivery |
Double fan/battery module included in scope of delivery |
Double fan/battery module included in scope of delivery |
Double fan/battery module included in scope of delivery |
Double fan/battery module included in scope of delivery |
Double fan/battery module included in scope of delivery |
||
DC supply voltage |
||||||||
|
V |
24 |
24 |
24 |
24 |
24 |
24 |
|
|
V |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
|
Consumed current typical |
mA |
700 |
1 000 |
700 |
1 000 |
1 900 |
1 900 |
|
|
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
||
Making current, typ. |
A |
5 |
5 |
5 |
5 |
5 |
5 |
|
Active power loss typical |
W |
17 |
24 |
17 |
24 |
46 |
46 |
|
Ambient temperature, during |
||||||||
|
°C (°F) |
-25 ... +55 (-13 ... +131) |
-25 ... +55 (-13 ... +131) |
-25 ... +55 (-13 ... +131) |
-25 ... +55 (-13 ... +131) |
-25 ... +55 (-13 ... +131) |
-25 ... +55 (-13 ... +131) |
|
|
°C (°F) |
-40 ... +70 (-40 ... +158) |
-40 ... +70 (-40 ... +158) |
-40 ... +70 (-40 ... +158) |
-40 ... +70 (-40 ... +158) |
-40 ... +70 (-40 ... +158) |
-40 ... +70 (-40 ... +158) |
|
|
°C (°F) |
0 ... 55 (32 ... 131) |
0 ... 55 (32 ... 131) |
0 ... 55 (32 ... 131) |
0 ... 55 (32 ... 131) |
0 ... 55 (32 ... 131) |
0 ... 55 (32 ... 131) |
|
|
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
||
Relative humidity during operation |
% |
5 ... 95 |
5 ... 95 |
5 ... 95 |
5 ... 95 |
5 ... 95 |
5 ... 95 |
|
Air pressure |
hPa |
620 ... 1 060 |
620 ... 1 060 |
620 ... 1 060 |
620 ... 1 060 |
620 ... 1 060 |
620 ... 1 060 |
|
Degree of protection |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
||
Height |
mm (in) |
380 (14.96063) |
380 (14.96063) |
380 (14.96063) |
380 (14.96063) |
380 (14.96063) |
380 (14.96063) |
|
Width |
mm (in) |
50 (1.9685) |
50 (1.9685) |
50 (1.9685) |
50 (1.9685) |
50 (1.9685) |
50 (1.9685) |
|
Depth |
mm (in) |
270 (10.62992) |
270 (10.62992) |
270 (10.62992) |
270 (10.62992) |
270 (10.62992) |
270 (10.62992) |
|
|
When the spacer is removed 230 mm (9.05 in) deep |
When the spacer is removed 230 mm (9.05 in) deep |
When the spacer is removed 230 mm (9.05 in) deep |
When the spacer is removed 230 mm (9.05 in) deep |
When the spacer is removed 230 mm (9.05 in) deep |
When the spacer is removed 230 mm (9.05 in) deep |
||
Net weight |
g (lb (avoirdupois)) |
3 600 (7.93664) |
3 600 (7.93664) |
3 600 (7.93664) |
3 600 (7.93664) |
4 400 (9.70034) |
4 400 (9.70034) |
|
Digital inputs |
||||||||
Number of digital inputs |
12 |
12 |
12 |
12 |
12 |
12 |
||
DC input voltage |
||||||||
|
V |
24 |
24 |
24 |
24 |
24 |
24 |
|
|
V |
15 ... 30 |
15 ... 30 |
15 ... 30 |
15 ... 30 |
15 ... 30 |
15 ... 30 |
|
|
V |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
|
Electrical isolation |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
||
|
Yes, in groups of 6 |
Yes, in groups of 6 |
Yes, in groups of 6 |
Yes, in groups of 6 |
Yes, in groups of 6 |
Yes, in groups of 6 |
||
Current consumption for "1" signal level, typ. |
mA |
9 |
9 |
9 |
9 |
9 |
9 |
|
Input delay time for |
||||||||
|
µs |
50 |
50 |
50 |
50 |
50 |
50 |
|
|
µs |
150 |
150 |
150 |
150 |
150 |
150 |
|
Digital inputs/outputs |
||||||||
Number of digital I/Os |
16 |
16 |
16 |
16 |
16 |
16 |
||
Parameterization possibility of the digital I/Os |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
||
If used as an input |
||||||||
DC input voltage |
||||||||
|
V |
24 |
24 |
24 |
24 |
24 |
24 |
|
|
V |
15 ... 30 |
15 ... 30 |
15 ... 30 |
15 ... 30 |
15 ... 30 |
15 ... 30 |
|
|
V |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
-3 ... +5 |
|
Electrical isolation |
No |
No |
No |
No |
No |
No |
||
Current consumption for "1" signal level, typ. |
mA |
9 |
9 |
9 |
9 |
9 |
9 |
|
Input delay time for |
||||||||
|
µs |
5 |
5 |
5 |
5 |
5 |
5 |
|
|
µs |
50 |
50 |
50 |
50 |
50 |
50 |
|
Measuring input reproducibility |
µs |
5 |
5 |
5 |
5 |
5 |
5 |
|
Measuring input resolution |
µs |
1 |
1 |
1 |
1 |
1 |
1 |
|
If used as an output |
||||||||
Load voltage |
||||||||
|
V |
24 |
24 |
24 |
24 |
24 |
24 |
|
|
V |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
20.4 ... 28.8 |
|
Electrical isolation |
No |
No |
No |
No |
No |
No |
||
Current carrying capacity for each output, max. |
mA |
500 |
500 |
500 |
500 |
500 |
500 |
|
Leakage current, max. |
mA |
2 |
2 |
2 |
2 |
2 |
2 |
|
Output delay for |
||||||||
|
µs |
150 |
150 |
150 |
150 |
150 |
150 |
|
|
µs |
400 |
400 |
400 |
400 |
400 |
400 |
|
|
µs |
75 |
75 |
75 |
75 |
75 |
75 |
|
|
µs |
150 |
150 |
150 |
150 |
150 |
150 |
|
|
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
||
Cam output reproducibility |
µs |
10 |
10 |
10 |
10 |
10 |
10 |
|
Cam output resolution |
µs |
1 |
1 |
1 |
1 |
1 |
1 |
|
Switching frequency of the outputs for |
||||||||
|
Hz |
100 |
100 |
100 |
100 |
100 |
100 |
|
|
Hz |
2 |
2 |
2 |
2 |
2 |
2 |
|
|
Hz |
11 |
11 |
11 |
11 |
11 |
11 |
|
Short-circuit protection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
||
Additional technical data |
||||||||
Back-up of non-volatile data |
||||||||
|
unlimited buffer duration |
unlimited buffer duration |
unlimited buffer duration |
unlimited buffer duration |
unlimited buffer duration |
unlimited buffer duration |
||
|
d |
4 |
4 |
4 |
4 |
4 |
4 |
|
|
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
||
Approvals |
||||||||
|
cULus |
cULus |
cULus |
cULus |
cULus |
cULus |
||
|
cULus |
cULus |
cULus |
cULus |
cULus |
cULus |
||
|
C-Tick |
C-Tick |
C-Tick |
C-Tick |
C-Tick |
C-Tick |
||
|
KCC |
KCC |
KCC |
KCC |
KCC |
KCC |
Order number |
|
6AG1435-2AD00-4AA0 |
6AG1455-2AD00-4AA0 |
|
---|---|---|---|---|
product brand name |
SIPLUS |
SIPLUS |
||
Product type designation |
D435-2 DP/PN SIPLUS |
D455-2 DP/PN SIPLUS |
||
Performance class for motion control system |
STANDARD Performance |
ULTRA-HIGH Performance |
||
Version of the motion control system |
Multiple-axis system |
Multiple-axis system |
||
PLC and motion control performance |
||||
Number of axes maximum |
32 |
128 |
||
Minimum PROFIBUS cycle clock |
ms |
1 |
1 |
|
Minimum PROFINET send cycle clock |
ms |
0.25 |
0.25 |
|
Minimum servo cycle clock |
ms |
0.25 |
0.25 |
|
Minimum interpolator cycle clock |
ms |
0.25 |
0.25 |
|
Minimum servo cycle clock note |
0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST |
0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST |
||
Integrated drive control |
||||
Maximum number of axes for integrated drive control |
||||
|
6 |
6 |
||
|
6 |
6 |
||
|
12 |
12 |
||
|
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x |
||
Memory |
||||
RAM (work memory) |
Mbyte |
86 |
320 |
|
Additional RAM work memory for Java applications |
Mbyte |
20 |
20 |
|
RAM disk (load memory) |
Mbyte |
41 |
76 |
|
Retentive memory |
kbyte |
364 |
512 |
|
Persistent memory (user data on CF) |
Mbyte |
300 |
300 |
|
Communication |
||||
DRIVE-CLiQ Interfaces |
6 |
6 |
||
USB Interfaces |
2 |
2 |
||
Industrial Ethernet Interfaces |
2 |
2 |
||
PROFIBUS Interfaces |
2 |
2 |
||
|
Equidistant and isochronous; Can be configured as master or slave |
Equidistant and isochronous; Can be configured as master or slave |
||
PROFINET Interfaces |
1 |
1 |
||
|
1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD) |
1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD) |
||
General technical data |
||||
Fan |
Double fan/battery module included in scope of delivery |
|||
DC supply voltage |
||||
|
V |
24 |
24 |
|
|
V |
20.4 ... 28.8 |
20.4 ... 28.8 |
|
Consumed current typical |
mA |
1 000 |
1 900 |
|
|
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
||
Making current, typ. |
A |
5 |
5 |
|
Active power loss typical |
W |
24 |
46 |
|
Ambient temperature, during |
||||
|
°C (°F) |
-25 ... +55 (-13 ... +131) |
-25 ... +55 (-13 ... +131) |
|
|
°C (°F) |
-40 ... +70 (-40 ... +158) |
-40 ... +70 (-40 ... +158) |
|
|
°C (°F) |
0 ... 55 (32 ... 131) |
0 ... 55 (32 ... 131) |
|
|
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft). |
||
Relative humidity |
||||
|
% |
0 ... 100 |
0 ... 100 |
|
|
condensation/frost permitted (no commissioning in bedewed state) |
condensation/frost permitted (no commissioning in bedewed state) |
||
Conformal coating |
Yes |
Yes |
||
Resistance |
||||
|
Yes |
Yes |
||
|
Class 3B2 mold and fungal spores (except fauna); For operation, the plug covers included in delivery must be left on the unused interfaces! |
Class 3B2 mold and fungal spores (except fauna); For operation, the plug covers included in delivery must be left on the unused interfaces! |
||
|
Yes |
Yes |
||
|
Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation. |
Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation. |
||
Air pressure |
hPa |
620 ... 1 060 |
620 ... 1 060 |
|
Degree of protection |
IP20 |
IP20 |
||
Height |
mm (in) |
380 (14.96063) |
380 (14.96063) |
|
Width |
mm (in) |
50 (1.9685) |
50 (1.9685) |
|
Depth |
mm (in) |
270 (10.62992) |
270 (10.62992) |
|
|
When the spacer is removed 230 mm (9.05 in) deep |
When the spacer is removed 230 mm (9.05 in) deep |
||
Net weight |
g (lb (avoirdupois)) |
3 600 (7.93664) |
4 400 (9.70034) |
|
Digital inputs |
||||
Number of digital inputs |
12 |
12 |
||
DC input voltage |
||||
|
V |
24 |
24 |
|
|
V |
15 ... 30 |
15 ... 30 |
|
|
V |
-3 ... +5 |
-3 ... +5 |
|
Electrical isolation |
Yes |
Yes |
||
|
Yes, in groups of 6 |
Yes, in groups of 6 |
||
Current consumption for "1" signal level, typ. |
mA |
9 |
9 |
|
Input delay time for |
||||
|
µs |
50 |
50 |
|
|
µs |
150 |
150 |
|
Digital inputs/outputs |
||||
Number of digital I/Os |
16 |
16 |
||
Parameterization possibility of the digital I/Os |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
||
If used as an input |
||||
DC input voltage |
||||
|
V |
24 |
24 |
|
|
V |
15 ... 30 |
15 ... 30 |
|
|
V |
-3 ... +5 |
-3 ... +5 |
|
Electrical isolation |
No |
No |
||
Current consumption for "1" signal level, typ. |
mA |
9 |
9 |
|
Input delay time for |
||||
|
µs |
5 |
5 |
|
|
µs |
50 |
50 |
|
Measuring input reproducibility |
µs |
5 |
5 |
|
Measuring input resolution |
µs |
1 |
1 |
|
If used as an output |
||||
Load voltage |
||||
|
V |
24 |
24 |
|
|
V |
20.4 ... 28.8 |
20.4 ... 28.8 |
|
Electrical isolation |
No |
No |
||
Current carrying capacity for each output, max. |
mA |
500 |
500 |
|
Leakage current, max. |
mA |
2 |
2 |
|
Output delay for |
||||
|
µs |
150 |
150 |
|
|
µs |
400 |
400 |
|
|
µs |
75 |
75 |
|
|
µs |
150 |
150 |
|
|
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
||
Cam output reproducibility |
µs |
10 |
10 |
|
Cam output resolution |
µs |
1 |
1 |
|
Switching frequency of the outputs for |
||||
|
Hz |
100 |
100 |
|
|
Hz |
2 |
2 |
|
|
Hz |
11 |
11 |
|
Short-circuit protection |
Yes |
Yes |
||
Additional technical data |
||||
Back-up of non-volatile data |
||||
|
unlimited buffer duration |
unlimited buffer duration |
||
|
d |
4 |
4 |
|
|
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
||
Approvals |
||||
|
cULus |
cULus |
||
|
cULus |
cULus |
||
|
C-Tick |
C-Tick |
||
|
KCC |
KCC |
说明 |
订货号 |
---|---|
用于 SIMOTION D4x5-2 的附件 |
|
双风扇/电池模块 包括电池 用于 SIMOTION D4x5-2 的备件 |
6FC5348-0AA02-0AA0 |
电池 风扇/电池模块的备件 |
6FC5247-0AA18-0AA0 |
外部风冷密封 (1 包 = 10 件) 对于外部风冷,控制单元的散热片安装在控制柜外。 需要使用一个密封,以便能够将 D445-2/D455-2 气密性安装在后部柜板中。 |
6FC5348-0AA07-0AA0 |
用于 PROFIBUS 的附件 |
|
PROFIBUS RS485 总线连接器,带有斜角电缆出口 (35°) 和螺钉型端子 **传输速率 12 Mbit/s |
|
|
6ES7972-0BA42-0A0 |
|
6ES7972-0BB42-0A0 |
PROFIBUS Fast Connect RS485 总线连接器,带有斜角电缆出口 (35°) 和绝缘刺破端子 **传输速率 12 Mbit/s |
|
|
6ES7972-0BA60-0A0 |
|
6ES7972-0BB60-0A0 |
PROFIBUS 适配插头 用于提升 PROFIBUS 连接器以提供更大的接线空间 |
6FX2003-0BB00 |
PROFINET 附件(接口 X150) |
|
RJ45 FastConnect 连接器,用于工业以太网/PROFINET 145°电缆引出线 |
|
|
6GK1901-1BB30-0AA0 |
|
6GK1901-1BB30-0AB0 |
|
6GK1901-1BB30-0AE0 |