工控系统及装备
D445-2DP/PN6AU1445-2AD00-0AA0
发布时间:2015-12-28 13:14:47 产品编号:GY-5-69801292  分享
价格:88.00/台
品牌:Siemens/西门子
起订:1台
供应:100台
发货:1天内
信息标签:D445-2DP/PN6AU1445-2AD00-0AA0,供应,电子、电工,工控系统及装备

点击这里进行电话呼叫
点击这里QQ咨询
联系时一定要说在【贸易商务资源网】看到的将给您优惠!如果您也想和该公司一样在网站发信息有好排名,点击立即免费注册,发布产品推广
 6AU1445-2AD00-0AA0

SIMOTION DRIVE-baseD ConTROL UNIT D445-2 DP/PN; PROGRAMMABLE MOTION CONTROLLER; HIGH PERFORMANCE; INTERFACES: 12 DI, 16 DI/DO, 6 DRIVE-CLIQ, 2 PROFIBUS, 3 PROFINET PORTS, 2 ETHERNET, 2 USB, 1 OPTION SLOT; INCL. DUAL FAN / BATTERY MODULE AND BATTERY


联  系  人 :章  鹏  ( 销售工程师 )
24小时销售技术服务热线 : 15921903060
电话( Tel ): +86 – 021 - 31129605
传真( Fax ): +86-021-67633621          
邮箱( Email ):2968525017 @qq.com

Order number

 

6AU1425-2AA00-0AA0

6AU1425-2AD00-0AA0

6AU1435-2AA00-0AA0

6AU1435-2AD00-0AA0

6AU1445-2AD00-0AA0

6AU1455-2AD00-0AA0

product brand name

 

SIMOTION

SIMOTION

SIMOTION

SIMOTION

SIMOTION

SIMOTION

Product type designation

 

D425-2 DP

D425-2 DP/PN

D435-2 DP

D435-2 DP/PN

D445-2 DP/PN

D455-2 DP/PN

Performance class for motion control system

 

BASIC Performance

BASIC Performance

STANDARD Performance

STANDARD Performance

HIGH Performance

ULTRA-HIGH Performance

Version of the motion control system

 

Multiple-axis system

Multiple-axis system

Multiple-axis system

Multiple-axis system

Multiple-axis system

Multiple-axis system

PLC and motion control performance

             

Number of axes maximum

 

16

16

32

32

64

128

Minimum PROFIBUS cycle clock

ms

1

1

1

1

1

1

Minimum PROFINET send cycle clock

ms

--

0.25

--

0.25

0.25

0.25

Minimum servo cycle clock

ms

0.5

0.5

0.5

0.25

0.25

0.25

Minimum interpolator cycle clock

ms

0.5

0.5

0.5

0.25

0.25

0.25

Minimum servo cycle clock note

 

--

--

--

0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

Integrated drive control

             

Maximum number of axes for integrated drive control

             
  • ● servo

 

6

6

6

6

6

6

  • ● vector

 

6

6

6

6

6

6

  • ● V/f

 

12

12

12

12

12

12

  • ● note

 

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Memory

             

RAM (work memory)

Mbyte

64

64

86

86

160

320

Additional RAM work memory for Java applications

Mbyte

20

20

20

20

20

20

RAM disk (load memory)

Mbyte

31

31

41

41

56

76

Retentive memory

kbyte

364

364

364

364

512

512

Persistent memory (user data on CF)

Mbyte

300

300

300

300

300

300

Communication

             

DRIVE-CLiQ Interfaces

 

4

4

6

6

6

6

USB Interfaces

 

2

2

2

2

2

2

Industrial Ethernet Interfaces

 

3

2

3

2

2

2

PROFIBUS Interfaces

 

2

2

2

2

2

2

  • ● note

 

Equidistant and isochronous; Can be configured as master or slave

Equidistant and isochronous; Can be configured as master or slave

Equidistant and isochronous; Can be configured as master or slave

Equidistant and isochronous; Can be configured as master or slave

Equidistant and isochronous; Can be configured as master or slave

Equidistant and isochronous; Can be configured as master or slave

PROFINET Interfaces

 

0

1

0

1

1

1

  • ● note

 

--

1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

--

1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

General technical data

             

Fan

 

Double fan/battery module included in scope of delivery

Double fan/battery module included in scope of delivery

Double fan/battery module included in scope of delivery

Double fan/battery module included in scope of delivery

Double fan/battery module included in scope of delivery

Double fan/battery module included in scope of delivery

DC supply voltage

             
  • ● rated value

V

24

24

24

24

24

24

  • ● permissible range

V

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

Consumed current typical

mA

700

1 000

700

1 000

1 900

1 900

  • ● Note

 

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

Making current, typ.

A

5

5

5

5

5

5

Active power loss typical

W

17

24

17

24

46

46

Ambient temperature, during

             
  • ● long-term storage

°C (°F)

-25 ... +55 (-13 ... +131)

-25 ... +55 (-13 ... +131)

-25 ... +55 (-13 ... +131)

-25 ... +55 (-13 ... +131)

-25 ... +55 (-13 ... +131)

-25 ... +55 (-13 ... +131)

  • ● transport

°C (°F)

-40 ... +70 (-40 ... +158)

-40 ... +70 (-40 ... +158)

-40 ... +70 (-40 ... +158)

-40 ... +70 (-40 ... +158)

-40 ... +70 (-40 ... +158)

-40 ... +70 (-40 ... +158)

  • ● operation

°C (°F)

0 ... 55 (32 ... 131)

0 ... 55 (32 ... 131)

0 ... 55 (32 ... 131)

0 ... 55 (32 ... 131)

0 ... 55 (32 ... 131)

0 ... 55 (32 ... 131)

  • — note

 

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Relative humidity during operation

%

5 ... 95

5 ... 95

5 ... 95

5 ... 95

5 ... 95

5 ... 95

Air pressure

hPa

620 ... 1 060

620 ... 1 060

620 ... 1 060

620 ... 1 060

620 ... 1 060

620 ... 1 060

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

IP20

Height

mm (in)

380 (14.96063)

380 (14.96063)

380 (14.96063)

380 (14.96063)

380 (14.96063)

380 (14.96063)

Width

mm (in)

50 (1.9685)

50 (1.9685)

50 (1.9685)

50 (1.9685)

50 (1.9685)

50 (1.9685)

Depth

mm (in)

270 (10.62992)

270 (10.62992)

270 (10.62992)

270 (10.62992)

270 (10.62992)

270 (10.62992)

  • ● Note

 

When the spacer is removed 230 mm (9.05 in) deep

When the spacer is removed 230 mm (9.05 in) deep

When the spacer is removed 230 mm (9.05 in) deep

When the spacer is removed 230 mm (9.05 in) deep

When the spacer is removed 230 mm (9.05 in) deep

When the spacer is removed 230 mm (9.05 in) deep

Net weight

g (lb (avoirdupois))

3 600 (7.93664)

3 600 (7.93664)

3 600 (7.93664)

3 600 (7.93664)

4 400 (9.70034)

4 400 (9.70034)

Digital inputs

             

Number of digital inputs

 

12

12

12

12

12

12

DC input voltage

             
  • ● rated value

V

24

24

24

24

24

24

  • ● for signal "1"

V

15 ... 30

15 ... 30

15 ... 30

15 ... 30

15 ... 30

15 ... 30

  • ● for signal "0"

V

-3 ... +5

-3 ... +5

-3 ... +5

-3 ... +5

-3 ... +5

-3 ... +5

Electrical isolation

 

Yes

Yes

Yes

Yes

Yes

Yes

  • ● note

 

Yes, in groups of 6

Yes, in groups of 6

Yes, in groups of 6

Yes, in groups of 6

Yes, in groups of 6

Yes, in groups of 6

Current consumption for "1" signal level, typ.

mA

9

9

9

9

9

9

Input delay time for

             
  • ● signal "0" → "1", typ.

µs

50

50

50

50

50

50

  • ● signal "1" → "0", typ.

µs

150

150

150

150

150

150

Digital inputs/outputs

             

Number of digital I/Os

 

16

16

16

16

16

16

Parameterization possibility of the digital I/Os

 

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

If used as an input

             

DC input voltage

             
  • ● rated value

V

24

24

24

24

24

24

  • ● for signal "1"

V

15 ... 30

15 ... 30

15 ... 30

15 ... 30

15 ... 30

15 ... 30

  • ● for signal "0"

V

-3 ... +5

-3 ... +5

-3 ... +5

-3 ... +5

-3 ... +5

-3 ... +5

Electrical isolation

 

No

No

No

No

No

No

Current consumption for "1" signal level, typ.

mA

9

9

9

9

9

9

Input delay time for

             
  • ● signal "0" → "1", typ.

µs

5

5

5

5

5

5

  • ● signal "1" → "0", typ.

µs

50

50

50

50

50

50

Measuring input reproducibility

µs

5

5

5

5

5

5

Measuring input resolution

µs

1

1

1

1

1

1

If used as an output

             

Load voltage

             
  • ● rated value

V

24

24

24

24

24

24

  • ● permissible range

V

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

20.4 ... 28.8

Electrical isolation

 

No

No

No

No

No

No

Current carrying capacity for each output, max.

mA

500

500

500

500

500

500

Leakage current, max.

mA

2

2

2

2

2

2

Output delay for

             
  • ● signal "0" → "1", typ.

µs

150

150

150

150

150

150

  • ● signal "0" → "1", max.

µs

400

400

400

400

400

400

  • ● signal "1" → "0", typ.

µs

75

75

75

75

75

75

  • ● signal "1" → "0", max.

µs

150

150

150

150

150

150

  • — note

 

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Cam output reproducibility

µs

10

10

10

10

10

10

Cam output resolution

µs

1

1

1

1

1

1

Switching frequency of the outputs for

             
  • ● resistive load, max.

Hz

100

100

100

100

100

100

  • ● inductive load, max.

Hz

2

2

2

2

2

2

  • ● lamp load, max.

Hz

11

11

11

11

11

11

Short-circuit protection

 

Yes

Yes

Yes

Yes

Yes

Yes

Additional technical data

             

Back-up of non-volatile data

             
  • ● of retentive data

 

unlimited buffer duration

unlimited buffer duration

unlimited buffer duration

unlimited buffer duration

unlimited buffer duration

unlimited buffer duration

  • ● of real-time clock, min.

d

4

4

4

4

4

4

  • ● note

 

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

Approvals

             
  • ● USA

 

cULus

cULus

cULus

cULus

cULus

cULus

  • ● Canada

 

cULus

cULus

cULus

cULus

cULus

cULus

  • ● Australia

 

C-Tick

C-Tick

C-Tick

C-Tick

C-Tick

C-Tick

  • ● Korea

 

KCC

KCC

KCC

KCC

KCC

KCC


Order number

 

6AG1435-2AD00-4AA0

6AG1455-2AD00-4AA0

product brand name

 

SIPLUS

SIPLUS

Product type designation

 

D435-2 DP/PN SIPLUS

D455-2 DP/PN SIPLUS

Performance class for motion control system

 

STANDARD Performance

ULTRA-HIGH Performance

Version of the motion control system

 

Multiple-axis system

Multiple-axis system

PLC and motion control performance

     

Number of axes maximum

 

32

128

Minimum PROFIBUS cycle clock

ms

1

1

Minimum PROFINET send cycle clock

ms

0.25

0.25

Minimum servo cycle clock

ms

0.25

0.25

Minimum interpolator cycle clock

ms

0.25

0.25

Minimum servo cycle clock note

 

0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

0,5 ms in conjunction with integrated SINAMICS S120 drives (SINAMICS Integrated); 0.25 ms in conjunction with SERVO-FAST and IPO-FAST

Integrated drive control

     

Maximum number of axes for integrated drive control

     
  • ● servo

 

6

6

  • ● vector

 

6

6

  • ● V/f

 

12

12

  • ● note

 

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x

Memory

     

RAM (work memory)

Mbyte

86

320

Additional RAM work memory for Java applications

Mbyte

20

20

RAM disk (load memory)

Mbyte

41

76

Retentive memory

kbyte

364

512

Persistent memory (user data on CF)

Mbyte

300

300

Communication

     

DRIVE-CLiQ Interfaces

 

6

6

USB Interfaces

 

2

2

Industrial Ethernet Interfaces

 

2

2

PROFIBUS Interfaces

 

2

2

  • ● note

 

Equidistant and isochronous; Can be configured as master or slave

Equidistant and isochronous; Can be configured as master or slave

PROFINET Interfaces

 

1

1

  • ● note

 

1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

1 interface with 3 ports onboard 1 interface with 4 ports optional via CBE30-2 functionality: - supports PROFINET IO with IRT and RT - configurable as PROFINET IO Control and/or device - supports media redundancy (MRP and MRPD)

General technical data

     

Fan

 

Double fan/battery module included in scope of delivery

 

DC supply voltage

     
  • ● rated value

V

24

24

  • ● permissible range

V

20.4 ... 28.8

20.4 ... 28.8

Consumed current typical

mA

1 000

1 900

  • ● Note

 

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface

Making current, typ.

A

5

5

Active power loss typical

W

24

46

Ambient temperature, during

     
  • ● long-term storage

°C (°F)

-25 ... +55 (-13 ... +131)

-25 ... +55 (-13 ... +131)

  • ● transport

°C (°F)

-40 ... +70 (-40 ... +158)

-40 ... +70 (-40 ... +158)

  • ● operation

°C (°F)

0 ... 55 (32 ... 131)

0 ... 55 (32 ... 131)

  • — note

 

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (44.6 °F) per 1000 m (3281 ft).

Relative humidity

     
  • ● during operation

%

0 ... 100

0 ... 100

  • ● without condensation during operation maximum Note

 

condensation/frost permitted (no commissioning in bedewed state)

condensation/frost permitted (no commissioning in bedewed state)

Conformal coating

 

Yes

Yes

Resistance

     
  • ● to biologically active substances conformity acc. to EN 60721-3-3

 

Yes

Yes

  • — Note

 

Class 3B2 mold and fungal spores (except fauna); For operation, the plug covers included in delivery must be left on the unused interfaces!

Class 3B2 mold and fungal spores (except fauna); For operation, the plug covers included in delivery must be left on the unused interfaces!

  • ● to chemically active substances conformity acc. to EN 60721-3-3

 

Yes

Yes

  • — Note

 

Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation.

Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation.

Air pressure

hPa

620 ... 1 060

620 ... 1 060

Degree of protection

 

IP20

IP20

Height

mm (in)

380 (14.96063)

380 (14.96063)

Width

mm (in)

50 (1.9685)

50 (1.9685)

Depth

mm (in)

270 (10.62992)

270 (10.62992)

  • ● Note

 

When the spacer is removed 230 mm (9.05 in) deep

When the spacer is removed 230 mm (9.05 in) deep

Net weight

g (lb (avoirdupois))

3 600 (7.93664)

4 400 (9.70034)

Digital inputs

     

Number of digital inputs

 

12

12

DC input voltage

     
  • ● rated value

V

24

24

  • ● for signal "1"

V

15 ... 30

15 ... 30

  • ● for signal "0"

V

-3 ... +5

-3 ... +5

Electrical isolation

 

Yes

Yes

  • ● note

 

Yes, in groups of 6

Yes, in groups of 6

Current consumption for "1" signal level, typ.

mA

9

9

Input delay time for

     
  • ● signal "0" → "1", typ.

µs

50

50

  • ● signal "1" → "0", typ.

µs

150

150

Digital inputs/outputs

     

Number of digital I/Os

 

16

16

Parameterization possibility of the digital I/Os

 

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8)

If used as an input

     

DC input voltage

     
  • ● rated value

V

24

24

  • ● for signal "1"

V

15 ... 30

15 ... 30

  • ● for signal "0"

V

-3 ... +5

-3 ... +5

Electrical isolation

 

No

No

Current consumption for "1" signal level, typ.

mA

9

9

Input delay time for

     
  • ● signal "0" → "1", typ.

µs

5

5

  • ● signal "1" → "0", typ.

µs

50

50

Measuring input reproducibility

µs

5

5

Measuring input resolution

µs

1

1

If used as an output

     

Load voltage

     
  • ● rated value

V

24

24

  • ● permissible range

V

20.4 ... 28.8

20.4 ... 28.8

Electrical isolation

 

No

No

Current carrying capacity for each output, max.

mA

500

500

Leakage current, max.

mA

2

2

Output delay for

     
  • ● signal "0" → "1", typ.

µs

150

150

  • ● signal "0" → "1", max.

µs

400

400

  • ● signal "1" → "0", typ.

µs

75

75

  • ● signal "1" → "0", max.

µs

150

150

  • — note

 

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut

Cam output reproducibility

µs

10

10

Cam output resolution

µs

1

1

Switching frequency of the outputs for

     
  • ● resistive load, max.

Hz

100

100

  • ● inductive load, max.

Hz

2

2

  • ● lamp load, max.

Hz

11

11

Short-circuit protection

 

Yes

Yes

Additional technical data

     

Back-up of non-volatile data

     
  • ● of retentive data

 

unlimited buffer duration

unlimited buffer duration

  • ● of real-time clock, min.

d

4

4

  • ● note

 

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module

Approvals

     
  • ● USA

 

cULus

cULus

  • ● Canada

 

cULus

cULus

  • ● Australia

 

C-Tick

C-Tick

  • ● Korea

 

KCC

KCC

Accessories

说明

订货号

用于 SIMOTION D4x5-2 的附件

双风扇/电池模块

包括电池

用于 SIMOTION D4x5-2 的备件

6FC5348-0AA02-0AA0

电池

风扇/电池模块的备件

6FC5247-0AA18-0AA0

外部风冷密封

(1 包 = 10 件)

对于外部风冷,控制单元的散热片安装在控制柜外。

需要使用一个密封,以便能够将 D445-2/D455-2 气密性安装在后部柜板中。

6FC5348-0AA07-0AA0

用于 PROFIBUS 的附件

PROFIBUS RS485 总线连接器,带有斜角电缆出口 (35°) 和螺钉型端子

**传输速率 12 Mbit/s

 
  • 无 PG 接口

6ES7972-0BA42-0A0

  • 带 PG 接口

6ES7972-0BB42-0A0

PROFIBUS Fast Connect RS485 总线连接器,带有斜角电缆出口 (35°) 和绝缘刺破端子

**传输速率 12 Mbit/s

 
  • 无 PG 接口

6ES7972-0BA60-0A0

  • 带 PG 接口

6ES7972-0BB60-0A0

PROFIBUS 适配插头

用于提升 PROFIBUS 连接器以提供更大的接线空间

6FX2003-0BB00

PROFINET 附件(接口 X150)

RJ45 FastConnect 连接器,用于工业以太网/PROFINET

145°电缆引出线
10/100 Mbit/s

 
  • 1 包 = 1 件

6GK1901-1BB30-0AA0

  • 1 包 = 10 件

6GK1901-1BB30-0AB0

  • 1 包 = 50 件

6GK1901-1BB30-0AE0

联系方式
公司: 上海 赞国自动化科技有限公司
状态:离线 发送信件
姓名:章鹏(先生)
职位:销售经理
电话:021-31129605
手机:15921903060
传真:021-67633621
地区:上海-松江区
地址:上海市松江区思贤路1855弄91号
邮编:201600
QQ:2968525017
阿里旺旺:s7400plc
商铺:http://m.ceoie.com/s7200plc/
去 上海 赞国自动化科技有限公司怎么走?上图中的红点是 上海 赞国自动化科技有限公司在松江区的具体位置标注,操作左上角地图工具可以放大缩小哦。
相关信息
[工控系统及装备] 推荐供应
最新发布信息
点击分享到微信、朋友圈、QQ...
字母索引:  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z

首页 | 公司 | 求购 | 供应 | 商城 | 招商 | 展会 | 行情 | 品牌 | 产品

联系我们 | 刷新 | 返回顶部

©2004-2024  贸易商务资源网(ceoie.com)  版权所有