品牌:福禄克Fluke
起订:1台
供应:100台
发货:3天内
信息标签:回收Fluke 116/62 MAX+回收福禄克116,供应,仪器仪表,专用仪器仪表
深圳市华盛电子仪器有限公司
联 系 人: 曹先生 联 系 人: 陈小姐
手机 QQ 微信:18565890279 手机 QQ 微信:15907696558
长期专业回收、销售、租赁、维修、计量二手仪器仪表!!欢迎来电咨询
本公司主要回收、供应: 频谱分析仪,红外热像仪,信号发生器,电桥,电源,示波器,网络分析仪,手机综合测试仪,万用表、电池测试仪,红外热像仪、色彩分析仪等**名品牌产品。
Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.
Fluke 62 MAX+. Small in size. Big on toughness.
Specifications | |
Maximum voltage between any terminal and earth ground | 600 V |
Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Display | 6,000 counts, updates 4 per second |
Bar graph | 33 segments, updates 32 per second |
Operating Temperature | -10 °C to + 50 °C |
Storage Temperature | -40 °C to + 60 °C |
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life | 400 hours typical, without backlight |
Accuracy Specifications | ||
DC millivolts | Range | 600.0 mV |
Resolution | 0.1 mV | |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/Resolution | 6.000 V / 0.001 V |
Range/Resolution | 60.00 V / 0.01 V | |
Range/Resolution | 600.00 V / 0.1 V | |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
|
AC millivolts1 true-rms | Range | 600.0 mV |
Resolution | 0.1 mV | |
Accuracy | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms | Range/Resolution | 6.000 V / 0.001 V |
Range/Resolution | 60.00 V / 0.01 V | |
Range/Resolution | 600.0 V / 0.1 V | |
Accuracy | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
Continuity | Range | 600 Ω |
Resolution | 1 Ω | |
Accuracy | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. | |
Ohms | Range/Resolution | 600.0 Ω / 0.1 Ω |
Range/Resolution | 6.000 kΩ / 0.001 kΩ | |
Range/Resolution | 60.00 kΩ / 0.01 kΩ | |
Range/Resolution | 600.0 kΩ / 0.1 kΩ | |
Range/Resolution | 6.000 MΩ / 0.001 MΩ | |
Accuracy | 0.9 % + 1 | |
Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 1.5 % + 2 | |
Diode Test | Range/Resolution | 2.000 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/Resolution | 1000 nF / 1 nF |
Range/Resolution | 10.00 μF / 0.01 μF | |
Range/Resolution | 100.0 μF / 0.1 μF | |
Range/Resolution | 9999 μF / 1 μF | |
Range/Resolution | 100 μF to 1000 μF | |
Accuracy | 1.9% + 2 | |
Range/Resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
LoZ capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
Temperature2 (Type-K thermocouple) | Range/Resolution | -40 °C to 400 °C / 0.1 °C |
Accuracy | 1% + 102 | |
Range/Resolution | -40 °F to 752 °F / 0.2 °F | |
Accuracy | 1% + 182 | |
AC μamps true-rms (45 Hz to 500 Hz) | Range/Resolution | 600.0 μA / 0.1 μA |
Accuracy | 1.0% + 2 | |
DC μamps | Range/Resolution | 600.0 μA / 0.1 μA |
Accuracy | 1.0% + 2 | |
Hz (V or A input)2 | Range/Resolution | 99.99 Hz / 0.01 Hz |
Range/Resolution | 999.99 Hz / 0.1 Hz | |
Range/Resolution | 9.999 Hz / 0.001 Hz | |
Range/Resolution | 50.00 Hz / 0.01 Hz | |
Accuracy | 0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications | |
Size | 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
Weight | 550 g |
Warranty | 3 years |
Specifications | ||
Temperature Range |
-30 °C to 650 °C (-22 °F to 1202 °F) | |
Accuracy | ±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 |
|
Response Time (95%) | Fluke 62+ MAX | <300 ms (95% of reading) |
Spectral Response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical Resolution |
12:1 (calculated at 90% energy) | |
Display Resolution | 0.1 °C (0.2 °F) | |
Repeatability of Readings | ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater | |
Power | AA battery | |
Battery Life | 8 hours with laser and backlight on | |
Physical Specifications | Weight | 255 g (8.99 oz) |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | |
Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) | |
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F), (without battery) | |
Operating Humidity | 10 % to 90 % RH non-condensing at 30 °C (86 °F) | |
Operating Altitude | 2000 meters above mean sea level | |
Storage Altitude | 12,000 meters above mean sea level | |
IP Rating | IP 54 per IEC 60529 | |
Drop Test | 3 meters | |
Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and Agency Approval |
Compliance | EN/IEC 61010-1: 2001 |
Laser Safety | FDA and EN 60825-1 Class II |