品牌:Flyin
起订:1台
供应:100000台
发货:5天内
信息标签:密集波分复用器 AWG,供应,通讯产品,其他未分类
16通道200G无热AWG合波/解波模块
40通道100G有热AWG合波/解波模块
41通道100G无热AWG合波/解波模块
96通道50G有热AWG合波/解波模块
该组件是专为DWDM在C波段内使用的,在不同的环境条件下降低设备的功耗, AWG包装是采用特殊设计可靠的热塑料,具有较低的热传导,工作组的工作温度通过用箔加热器或抗珀耳帖TEC热敏电阻温度传感器控制。可以选择不同的输入和输出光纤,如SM纤维,MM光纤和PM光纤,以满足不同的应用程序。我们也可以提供不同的包装,不同的产品,包括特殊的金属盒和 19“ 1U机架式。
Optical Specification (Flat Top Thermal AWG)
Parameters |
Condition |
Specs |
Units |
||
Min |
Typ |
Max |
|||
Number of Channels |
|
40 |
|
||
Number Channel Spacing |
100GHz |
100 |
GHz |
||
Cha. Center Wavelength |
ITU frequency. |
C -band |
nm |
||
Clear Channel Passband |
|
±0.1 |
nm |
||
Wavelength Stability |
Maximum range of the wavelength error of all channels and temperatures in average polarization. |
±0.05 |
nm |
||
-1 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.4 |
|
|
nm |
-3 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.6 |
|
|
nm |
Optical Insertion Loss at ITU grid |
Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations. |
|
4.5 |
6.0 |
dB |
Adjacent Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the adjacent channels. |
25 |
|
|
dB |
Non-Adjacent, Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the nonadjacent channels. |
30 |
|
|
dB |
Total Channel Isolation |
Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels. |
22 |
|
|
dB |
Insertion Loss Uniformity |
Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures. |
|
1.0 |
1.5 |
dB |
Directivity(Mux Only) |
Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n |
40 |
|
|
dB |
Insertion Loss Ripple |
Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port |
|
|
0.5 |
dB |
Optical Return loss |
Input & output ports |
40 |
|
|
dB |
PDL/Polarization Dependent Loss in Clear Channel Band |
Worst-case value measured in ITU band |
|
0.3 |
0.5 |
dB |
Polarization Mode Dispersion |
|
|
|
0.5 |
ps |
Maximum Optical Power |
|
|
|
23 |
dBm |
MUX/DEMUX input/ output Monitoring range |
|
-35 |
|
+23 |
dBm |
IL Represents the worst case over a +/-0.1nm window around the ITU wavelength
PDL was measured on average polarization over a +/- 0.1nm window around the ITU wavelength.