本着为“客户提供**的产品和**惠的价格以及**的售后服务”以宗旨,北京泰如电子科技有限公司在保证产品质量、性能的同时,还会定期回访,进行仪器与配件保养、维护及技术交流。让客户能得到**的服务、满意的价格、放心的使用。
5660B超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪音的放大。这款仪器具有以下性能:20 kHz~2 MHz带宽,可选的40 dB和60 dB电压增益。
5660C超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:500 Hz~2 MHz带宽,可选的40 dB和60 dB电压增益。
5662超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:50 kHz~2 MHz带宽,可选的34 dB和54 dB电压增益。
5670超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:50 kHz~10 MHz带宽,40 dB电压增益。
5676超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:50 kHz~20 MHz带宽,40 dB电压增益。
5678超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:200 kHz~40 MHz带宽,40 dB电压增益。
Olympus wideband series of Panametrics AC coupled, broadband preamplifiers provides very low noise amplification of ultrasonic signals ranging from 500 Hz to greater than 40 MHz. Specifically designed for use with ultrasonic flaw detection, thickness gaging, and acoustic emission instrumentation, our preamplifiers are a cost-effective solution in general applications requiring high gain/low-noise amplification of low amplitude ultrasonic signals.
Our preamplifiers are ruggedly housed, completely self-contained, simple to operate, battery or AC powered units. They offer performance features such as very low noise (5 µV peak-to-peak noise referred to the input in Model 5660B), input protection for high voltage transients such as transducer excitation pulses, and the ability to drive long coaxial cables (greater than 500 feet or 152 meters with Models 5660B and 5660C). Both fixed gain and switchable gain versions are available, and custom units with special gain or bandwidth are available on special order.
Certain ultrasonic applications require the addition of a separate preamplifier unit to standard test systems in order to provide the additional gain or broadband signal-to-noise enhancement necessary for optimum signal acquisition. This is often the case in industrial applications involving flaw detection or thickness gaging of thick sections of materials exhibiting high ultrasonic attenuation such as nodular cast iron, brass, bronze, austenitic steel, rubber, Teflon®, or reinforced composites. A preamplifier is also an important component of acoustic emission test systems that require amplification of low signal amplitude events and the ability to drive long cables from remotely located sensors.
Panametrics preamplifiers have also been used in many widely diversified research applications including seismic studies, determination of the size and number versus scattered frequency relationship for acoustic scatterers in water (gas bubbles, zooplankton), crack detection in graphite vacuum arc-melt electrodes, and biological tissue analysis.
The Model 5682 Ultrasonic Preamplifier provides low noise amplification of ultrasonic signals ranging from 500 KHz to 25 MHz. The preamplifier, housed in a rugged enclosure, is very small and lightweight making it ideally suited for remote applications. The preamplifier can be powered with either a single 9 V battery for up to 50 hours of continuous operation or a local 9 V to 13 V DC supply (customer supplied). When battery operated, a multicolored LED provides feedback on battery status. This preamplifier is ideal for AUT and TOFD scanning.
Inclusions: The unit is supplied with one 9 V alkaline battery. All cables are sold separately and are offered in a variety of lengths and connector styles to accommodate transducer, instrumentation, and applications requirements.
Potential increase in sensitivity using a tuned square wave pulser versus a spike pulser as a function of transducer center frequency. | |
Response using a Model 5073PR 75 MHz bandwidth pulser-receiver with a V215-BA-RM 50 MHz permanent delay contact transducer coupled to a 0.075 mm (0.003") metal shim | |
Spike excitation features sharp rise times adjusted by energy and damping values. | |
Square wave has controlled rise and fall times with directly adjustable voltage and pulse width. | |
A-scan comparison between 5073PR and 5072PR with 50 ohm damping and energy Position 1 to 5077PR set at 100 volts and tuned for frequency optimization. Gain set to noted dB level to normalize signal height from a 20 MHz delay line transducer. |
MODEL | 5660B | 5660C | 5662 | 5670 | 5676 | 5678 |
Voltage Gain (Inverting) |
40 and 60 dB Switchable (RL > 1K ohm) |
40 and 60 dB Switchable (RL > 1K ohm) |
34 and 54 dB Switchable (RL = 50 ohm) |
40 dB Fixed (RL = 50 ohm) |
40 dB Fixed (RL = 50 ohm) |
40 dB Fixed (RL = 50 ohm) |
Bandwidth (-3dB) |
20 kHz - 2 MH |
500 Hz - 2 MHz |
50 kHz - 5 MHz |
50 kHz - 10 MHz |
50 kHz - 20 MHz |
200 kHz - 40 MHz |
Equivalent Input Noise |
5 µV p-p | 5 µV p-p | 10 µV p-p | 15 µV p-p | 20 µV p-p | 30 µV p-p |
Input Resistance |
1M ohm | 1M ohm | 100K ohm | 100K ohm | 100K ohm | 100K ohm |
Input Capacitance (pf) |
approx. 320 | approx. 320 | approx. 80 | approx. 80 | approx. 80 | approx. 80 |
Input | ||||||
Protection | 300 V peak (Pulse Width <2 µs, 1% Maximum Duty Cycle) | |||||
Output | 5 V p-p (RL > 1 K ohm) | |||||
Voltage | 2 V p-p (RL = 50 ohm) | 2 V p-p (RL = 50 ohm) | ||||
Output | ||||||
Impedance |
50 ohms in series with 4.7 fd |
|||||
Max. Output | >500' (152 m) | 50' (15 m) | ||||
Power | 16 V ± 2 V supplied by 4 Alkaline 9 V, 655 mAh batteries | |||||
Requirements | Line operated units available. Add /110 VAC, /115 VAC, or /230 VAC to the Model Number (e.g. 5675/115 VAC). | |||||
Current Consumption |
28 mA | 28 mA | 28 mA | 32 mA | 32 mA | 36 mA |
Battery Life |
>40 hrs | >40 hrs | >40 hrs | >35 hrs | >35 hrs | >35 hrs |
Dimensions | 3" W x 2" H x 5" D (76 mm W x 51 mm H x 127 mm D) | |||||
Weight |
1.4 lbs. (0.64 kg) |
|||||
Operating Temperature |
32° F to 122° F (0° C to 50° C) |
*All specifications are subject to change without notice.
Voltage Gain: 30 dB @ 10 MHz
HighPassRollover: 0.5 MHz +/- 0.1 MHz
LowPassRollover: 31 MHz +/-1 MHz
Equivalent Input Noise: 11.5 µV RMS
Input Impedance: Nominally 700 ohms
Output Impedance: Nominally 50 ohms
Output Voltage: 2.5 V pk-pk
Protection: 500 V peak
Current Consumption: Nominally 14 mA
Power: 9 V alkaline battery or 9-13 V DC input (toggle switch)
Power Monitor: Three color LED for continuous power level indications
• Green: 7.0 - 9.0 V
• Yellow: 6.5 - 7 V
• Red: 5.0 - 6.5 V
• No light: <5.0 V (Low charge, replace battery)
BatteryLife:
>50 hours continuous operation
Connectors: Lemo® 00 Type
Dimensions: 2.25" x 4.3" x 1.1",
57.15 mm x 109.22 mm x 27.94 mm
Weight:
6.4 oz, 181 gr with battery;
4.8 oz, 136 gr without battery
Operating Temperature:
32° F to 122° F;
0° C to 50° C
Environmental: IP65