品牌:Olympus/010-57464568
起订:1只
供应:100只
发货:3天内
信息标签:Olympus/5058PR脉冲发生器,供应,仪器仪表,试验机
本着为“客户提供**的产品和**惠的价格以及**的售后服务”以宗旨,北京泰如电子科技有限公司在保证产品质量、性能的同时,还会定期回访,进行仪器与配件保养、维护及技术交流。让客户能得到**的服务、满意的价格、放心的使用。
5058PR高压超声脉冲发生器接收器专用于对声束衰减性强的材料的检测和测量应用。其脉冲发生器**高可发射900伏激励脉冲,从而可适当对低频探头进行补偿。
The Panametrics Model 5058PR High Voltage pulser-receiver is designed especially for ultrasonic test and measurement applications in attenuating mediums. The pulser section of the Model 5058PR can deliver up to 900 volts in an impulse type excitation pulse to appropriate low frequency transducers. The flexible receiver section provides switchable 40/60 dB gain with an additional 30 dB available from an integral low noise preamplifier. Four position high and low pass filters and 1 dB attenuation steps further optimize signal response.
A full range of front panel controls permits discrete calibrated settings or continuous adjustments for easy and repeatable instrument setup. The unit is packaged in a rack adaptable 19" (483 mm) wide enclosure.
Features & Benefits
• High voltage pulser, switched settings or continuously adjustable to 900 volts
• High gain, low noise broadband (10 MHz) receiver
• Pulse-echo and thru-transmission modes
• High isolation (80 dB) in thru-transmission mode
• 60 dB RF Gain
• Additional 30 dB gain available from internal auxiliary preamplifier
• Receiver attenuation range of 0 to 80 dB in 1 dB steps
• 6 dB vernier for fine adjustment
• Switchable high pass and low pass filters
• PRF rate switch selectable from 20 Hz to 2 kHz
• Controls permit either discrete, calibrated settings or continuous adjustment
Applications
Used with an analog or digital oscilloscope, the Model 5058PR can be the basis of a bench top measurement system for determination of material quality or properties. Flaw detection, time of flight, thickness, velocity, attenuation, and frequency content are investigated. The high voltage pulser and high gain receiver of the Model 5058PR make it particularly useful for applications that challenge the penetrating capability of conventional pulser/receivers in such materials as:
- coarse grain cast metals
- concrete, stone, soil or sand
- composites and fiberglass
- very thick plastics or rubber
- highly attenuating liquids, slurries or emulsions
- wood and fiberboard
- air gaps
Potential increase in sensitivity using a tuned square wave pulser versus a spike pulser as a function of transducer center frequency. | |
Response using a Model 5073PR 75 MHz bandwidth pulser-receiver with a V215-BA-RM 50 MHz permanent delay contact transducer coupled to a 0.075 mm (0.003") metal shim | |
Spike excitation features sharp rise times adjusted by energy and damping values. | |
Square wave has controlled rise and fall times with directly adjustable voltage and pulse width. | |
A-scan comparison between 5073PR and 5072PR with 50 ohm damping and energy Position 1 to 5077PR set at 100 volts and tuned for frequency optimization. Gain set to noted dB level to normalize signal height from a 20 MHz delay line transducer. |
Standard Inclusions
The Model 5058PR is shipped with two BCB-58-4 cables, one 50 ohm terminator, application detachable power/mains cord, and operating manual. An optional rack-mount kit is available and should be specified at time of ordering.
*All specifications are subject to change without notice.