仪器仪表
奥林巴斯Olympus斜轴表面探头
发布时间:2017-06-08 09:12:08 产品编号:GY-5-145911969  分享
价格:0.00/只
品牌:Olympus/010-57464568
起订:1只
供应:100只
发货:3天内
信息标签:奥林巴斯Olympus斜轴表面探头,供应,仪器仪表

点击这里进行电话呼叫
点击这里QQ咨询
联系时一定要说在【贸易商务资源网】看到的将给您优惠!如果您也想和该公司一样在网站发信息有好排名,点击立即免费注册,发布产品推广
奥林巴斯Olympus涡流探头  奥林巴斯Olympus斜轴表面探头   斜轴表面探头-奥林巴斯Olympus

斜轴表面探头-北京泰如专业供应平台  斜轴表面探头-欢迎来电索取价格以及产品资料010-57464568

奥林巴斯Olympus涡流探头/斜轴表面探头-北京泰如电子科技价格优惠,各种规格涡流探头

本着为“客户提供**的产品和**惠的价格以及**的售后服务”以宗旨,北京泰如电子科技有限公司在保证产品质量、性能的同时,还会定期回访,进行仪器与配件保养、维护及技术交流。让客户能得到**的服务、满意的价格、放心的使用。



The small coils and high frequency range of these detachable stainless-steel shaft probes make them ideal for the detection of surface breaking cracks. Their angled design enables the inspection of areas with restricted access.

Advantages

  • Suitabler for small defect detection.
  • Designed to reach areas inaccessible to standard probes.
  • Drop enables inspection around fasteners.
  • Available with Powerlink™ technology.
  • Wide selection of lengths, drops, and angles.
  • Available with bridge or reflection configuration.

Absolute bridge type probes

Rotating Scanner Probe
  • Internal reference coils ensure the best match to the test coil when using a Triax (Fischer™*) or Powerlink™ connector.
  • Shielded coil for higher resolution.
  • Detect cracks in all directions.
  • Probe-type commonly used worldwide.
  • Cost-effective option.

Olympus absolute bridge type probes give a clean and strong signal as shown.

* All brands are trademarks or registered trademarks of their respective owners and third-party entities.

Reflection type probes

Rotating Scanner Probe Also known as send-receive or driver-pickup
  • Provides a similar response to the absolute bridge probe.
  • Available with stacked or concentric driver and pickup coils.
  • Enables crack detection in all directions.
  • Withstand variations in temperature.
  • Operate over a wide frequency range.

Olympus reflection absolute type probes give a clean and strong signal as shown.

Type Coil Length Angle Drop Frequency Shaft Size Connector Part ID Item Number Cable ID Item Number
Angle Shaft Reflection Absolute 45° 6 in. (152.4 mm) 0.5 in. (12.7 mm) 50 kHz to 500 kHz 0.125 in. (3.17 mm) Powerlink™ 9230999.00 U8629476 9122083 U8800073
Angle Shaft Reflection Absolute 30° 6 in. (152.4 mm) 0.5 in. (12.7 mm) 50 kHz to 500 kHz 0.125 in. (3.17 mm) Triax Fisher 9231965 U8629480 SPO-6687 U8800538


Introduction

This paper is intended to provide information to help the user in selecting the right E.C. probe(s) for a given inspection. Using this data, best results will be achieved by optimizing the frequency and choosing a suitable instrument. 

The subject is divided into three sections -

1. Coil types available 

2. Typical applications 

3. New developents

1. COIL TYPES AVAILABLE

The early E.C. coils generally had either no core ( air core) or a ferrite center core only. Meter instruments were used almost exclusively and sensitivity was comparatively low, but in most cases adequate. Many inspections are still being done using this type of comparatively large, low sensitivity coils. 

Absolute Type Coils

A very widely used type coil is a 100 kHz with a diameter of .1 in. (2.5 mm) to .2 in. (5 mm) that fits most bridge type older meter instruments (Figure 1). The sensitivity is acceptable for long cracks that exceed the probe diameter by a factor of approximately 2, as the field is considerably larger than the coil size. This also produces a large edge effect.

widely used type coil is a 100 kHz with a diameter of .1 in. (2.5 mm) to .2 in. (5 mm)

Figure 1

A suitable alternative now offered is a smaller coil approximately .060 in. (1.5 mm) diameter with a shield (preferably ferrite) around it. This gives improved sensitivity particularly to short cracks and good isolation from edges, bolt heads, etc. 1

The older probes were normally calibrated using an infinitely long (to the coil) notch, .040 in. (1 mm)or ,020 in. (.5 mm), and their sensitivity will drop off rapidly with shorter notches. The new probes maintain their sensitivity with a notch approximately the internal diameter of the ferrite shield and will still detect a shorter one. 

Even meter instruments benefit from this type of coil, but probing speed is limited as the needle needs time to respond. Display-type instruments allow for much faster scanning. Larger surface type probes respond in a similar way to the above. Shielding produces similar improvements when looking for subsurface cracks or corrosion.

Differential coils

Figure 2 

Differential Type Coils

Differential coils have the attraction of built-in lift-off compensation. This has made them useful for many applications. 

The older types of coils had no ferrite shield and they were built just by placing two coils side-by-side (Figure 3). Later types added individual shields(Figure 4), but the greatest improvement to the sensitivity was achieved when both coils were placed within a common shield (Figure 5). Differential type probes are mostly used in small sizes for surface crack detection only.

two coils side-by-side

Figure 3

shielded

Figure 4

common sheild

Figure 5

In a probe of this type both coils are wound in opposition. Consequently, signals that affect both simultaneously will cancel out (such as lift- off). Normally the air point and the working point will be close, but some difference is present due to small coil variations. 

Normal scan direction is as shown (Figure 6), giving the typical display presentation. The double indication is, in fact helpful, as it doubles the size of the defect in the screen (Figure 7).

Normal Scan direction

Figure 6

detect screen

Figure 7

Sometimes it is necessary to scan in the same direction as the cracks (Figure 8). This is permissible and the result will be similar for a very short defect. A larger defect affecting both coils will tend to cancel out because they are in opposition, but in practice there are enough differences in angle and depth for this not to happen totally. In any case, the ends of the crack will show normally.

scanning in same direction as crack

FIgure 8


The probe body has a line to show the normal scan direction. These coils can be fitted in pencil, bore hole or molded probes to fit almost any shape.

Bridge and Reflection Coils

Older coils were normally connected to the two branches of a bridge configuration (Figure 9). Later coils have also been used in the reflection mode where separate coils are used for generating and detecting the eddy currents (Figure 10).

Bridge Configuration

Figure 9

Reflection Configuration

Figure 10

Bridge coils give generally good performance, particularly if the probe is designed for a specific application and frequency. Reflection coils will often give a greater gain and a wider frequency range of operation 
but they are more complicated to manufacture. They also have less drift. 2

Reflection probes are also used on special probe designs that rely on the transmit-receive principle to create a certain size/shape sensitive area (like the sliding type probes).

2. TYPICAL APPLICATIONS

Surface Cracks
Normal operating frequency: 

Aluminum - 100 kHz - 1 MHz 
Steel - 1 MHz - 2 MHz 
Inconel Titanium - 2 MHz - 5 MHz 

Probes available
Pencil types - Absolute or differential . Shielded or unshielded 
Surface types - Larger diameter probes can sometimes be used 
Sliding probes - For cracks starting under fastener heads 
Wheel probes - For bead seat radius, molded 

Subsurface Cracks

Frequency must be low enough to penetrate the required depth (use slide rule or graph attached). Minimum usable frequency is 100 HZ. 3 

Probes Available : 
Surface probes - Normally absolute shielded. Diameter can be as large as spacing between fasteners 
Encircling probes - Give better penetration. I.D. must be close to fastener head diameter 
Sliding probes - For fast directional inspection (reflection) 

Bore Hole Cracks

Frequency as for surface cracks 

Probes available: 
Absolute - (preferably shielded) in hand operated or scanner versions. 
Differential - (shielded or unshielded) - hand operated and scanner versions 

Probes can be expanding (contact type) or non-expanding (slightly below hole size) . Contact probes can be more sensitive to cracks (no lift - off distance) but they also generate scanning noise. Low frequency types can be used to penetrate through brass bushings. Automated systems can be implemented. 4

Coatings

Frequency varies with type of coating 
Non-conductive coatings can be considered as lift-off measurements. 
metallic coatings require good penetration, but as they are normally very thin, fairly high frequencies are usable. 

Standard absolute pencil and/or surface probes are suitable. 

Conductivity

Using a standard absolute pencil or surface probe and a conductivity sample, it is possible to identify different alloys with a standard instrument. More accurate measurements require special 
conductivity meters and probes. 5,6

Corrosion/Thickness

Frequency must be able to penetrate thickness required. Use EC slide rule or graph attached. 

Best results are obtained using shielded surface probes. 7,8

3. NEW DEVELOPMENTS

Aluminum Angle Inspection

The problem was to inspect aluminum angle for cracks in the opposite side (not accesible) in one pass and with high sensitivity. In order to cover the required width, the coil has a lift-off of about .1 in. (2.5 mm). 

A modified version of the sliding probe proved to be the best answer to several alternatives tried (Figure 11). A .020 in. maximum (15 mm) depth notch produced with a 1 in. diameter blade was detectable. 

Lift-off variations and edge effects could be identified as such on the display.

sliding probe

Figure 11 

Thin Probe

To inspect between two lugs spaced less than .080 in. (2 mm) apart, the probe had to be shielded and be completely unsensitive at the back (Figure 12)

Using stainless steel for strength, a shielded coil was placed at the tip . A nylon handle placed at 45° allowed for better access. Such a flat coil proved very sensitive to small cracks both in steel and aluminum.

Figure 12 

Small Sliding Probes

Used to inspect between fasteners in fuselage structures, a sliding probe is easier to handle than a small round probe. They give directional response with a frequency range of 1-100 kHz and penetration up to .100 in. (2.5 mm) 

Sliding Probe Transparent Lens Adjustment

The sensitive area of this type of sliding probe is the distance between the driver and pick-up sections. The lens is therefore adjusted to the required width of inspection (Figure 13).

adjusted lens

Figure 13


When scanning along a line of fasteners, this distance can also be optimized for best discrimination between the fastener indication and the defect . With no lens present, the probe is at its highest gain, but because of this it also gives a large indication for the fastener (Figure 14).

Figure 14

By allowing a thin lens, it is noticeable that the fastener indication has decreased, but the defect has not. Eventually a good compromise can be reached where the gain is not too high. The defect gives an indication that is clearly seen and the fastener only causes a comparatively small movement. A too wide lens will result in a very high gain setting and a decrease in sensitivity to short defects. 9

Figure 15 

Transparent Probe Holders

When calibrating a probe in a test block with small notches, it is difficult to optimize the indication with an opaque holder. The holder is needed for stability, so 
using a transparent material makes it possible to see the notch position (Figure 16) and make the calibration easier. It is also useful when scanning in confined areas or between fasteners to avoid running too close to the heads.

transparent probe holders

Figure 16 

High Gain Probes

Sometimes standard types of EC probes are not able to give a large enough indication for the defect. This may be due to geometry, defect size or a higher than normal lift-off . 

To achieve the extra gain, it is often possible to position a very small hybrid amplifier circuit within the probe body or in a separate small box close to it(Figure 17). This pre-amplifier can be tailored to a specific inspection if needed.

high gain probe

Figure 17

With this extra amplification the instrument gain can be lowered to a medium setting and the resultant signal will have a better signal-to-noise ratio than before. Care should be taken to ensure that too large of a signal does not saturate the instrument input. A quick check for this is to compare the lift- off with the edge effect. If both lines superimpose on each other, saturation is present and the gain should be lowered (there should always be a small angle separation). 

A typical application has been the testing of bore holes in disks with a lift-off of up to .020 in. (probe .040 in. under size), enabling the use of a single probe size. 

Extra gain has been needed to inspect aluminum-titanium sandwich structures. The titanium allows eddy currents to penetrate to the aluminum layer if the gain available is sufficient. Unfortunately, when the aluminum is covering the titanium, the eddy currents do not penetrate this as the conductivity is much lower than the aluminum, and it behaves like a shield. 

If more than one probe is needed, it is possible to multiplex several probes or coils and use a single instrument. 10

REFERENCES

1. "Shielded E.C. Probes" 
Process Laboratory Report 
The Physical Sciences Laboratory Branch, Directorate of Maintenance, 
Sacramento Air Logistics Center, McClellan A.F.B. Project No. 81-497-085, 
Donald M. Bailey 

2. "E. C. Development Activities" 
Walter J. Harris, Boeing Commercial Airplane Co., ATA 1981 

3. "Low Frequency E.C. Inspection of Aircraft Structure" 
D. J. Hagemaier and A. P. Steinberg, Douglas Aircraft Company ATA 1980 

4. "Update on Automated E.C. Inspection System" 
Art Thompson, G.E. Evendale, ATA 1983 

5. "Boeing Process Specification" , BAC 5946 

6. "evaluation of Heat Damage to Aluminum Aircraft Structures" 
D. J. Hagemaier, Douglas Aircraft Company, ATA 1981 

7. "A General Procedure for the Detection and Measurement of Corrosion in Aircraft Skins Using E.C. 
Equipment" 
J. Pellicer, Staveley NDT Technologies, Inc., NORTEC Division, ATA 1984 

8. "Aircraft Corrosion and Detection Methods" 
D. J. Hagemaier, A. H. Wendelbo, Jr., Douglas Aircraft Co., ATA 1984 

9. "Sliding Probes with Transparent Lens", Technical Bulletin 
J. Pellicer, Staveley NDT Technologies, Inc., NORTEC Division 

10. "Application Advancement in E.C. Using Pre-Amplifiers and Multiplexers " 
J. Pellicer, Staveley NDT Technologies, Inc., NORT EC Division, 
ASNT Spring Conference, Tulsa, OK 1986

Olympus的涡流探头包含Nortec和NDT工程的各种获得性品牌。我们提供10000多种标准的和用户定制型涡流探头、标准参考试块及配件。 本部分说明具有各种直径、频率、连接器类型的多种标准探头。

Olympus还提供可满足特殊检测应用要求的自定义探头。涡流探头的外形可以参照工件的轮廓或根据探头是否恰好装于固定架中的标准进行设计,以更快、更精准地完成检测操作。

北京泰如电子科技:检查解决方案助您提高生产力
北京泰如电子科技以技术为先导,为客户提供高效、**和安全的检测解决方案。我们设计、并维护超声波探伤仪,根据客户需求定制特殊规格探头,满足于各行业,代理工业工业内窥镜,X射线和涡流检测设备,为航空航天、电力、石油天然汽车和钢铁等行业应用制定专业检查方案。主要代理品牌:美国GE、德国KK、美国奥林巴斯(Olympus)、汕头汕超、美国泰克(Tektronix)、美国福禄克(FLUKE)、美国安捷伦(Agilent)、**固纬(GW)、香港优利德(UNI-T)、新美达(美柯达)、沪船(船牌)等。
主要经营:超声波探伤仪、无损检测仪器系列、示波器系列、安规测试仪系列、分析仪器系列、红外测温仪系列、行业专用仪器系列、电子测试仪器系列、环境监测仪器系列、力学仪器系列、电工测试仪器系列、通讯仪器仪表系列、通用监测仪器系列、工程监测仪器系列、计量检测仪器系列、气体检测仪器系列、其他测试仪器等。

奥林巴斯Olympus涡流探头一览表;





联系方式
公司:北京泰如电子科技有限公司
状态:离线 发送信件
姓名:张文庆(先生)
电话:010-57464568
手机:13699112842
地区:北京-通州区
地址:北京市通州区土桥中街140号金隅自由筑1-1-1706
邮编:100000
QQ:3081402071
商铺:http://m.ceoie.com/bjtrdz/
去北京泰如电子科技有限公司怎么走?上图中的红点是北京泰如电子科技有限公司在通州区的具体位置标注,操作左上角地图工具可以放大缩小哦。
相关信息
[仪器仪表] 推荐供应
最新发布信息
点击分享到微信、朋友圈、QQ...
字母索引:  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z

首页 | 公司 | 求购 | 供应 | 商城 | 招商 | 展会 | 行情 | 品牌 | 产品

联系我们 | 刷新 | 返回顶部

©2004-2024  贸易商务资源网(ceoie.com)  版权所有